Description
Product Type
Thin-Film Membrane (TFM®)
Dimension
40.125 in x 3.94 in
Product Specifications
Average Permeate Flow |
Average NaCl Rejection (%) |
Minimum NaCl Rejection (%) |
|
(GPD) | (m³/d) | ||
1,600 | 6.1 | 99.5 | 99.0 |
• Specifications are based on a 2000 mg/L NaCl solution at 420 psig operating pressure (2930kPa), 77deg.F,(25deg.C), 10% recovery, pH 6-7. Individual flux may vary +15%/ -15%. Average salt rejection after a minimum of 24 hours in continuous operation.
Operating and Cleaning Limits
Typical Operating Pressure | Typical Operating Flux | Maximum Operating Pressure | Maximum Temperature | pH Range, Optimum Rejection | pH Range, Continuous Operation | pH Range, Clean-In-Place (CIP) | Maximum Pressure Drop, Over An Element | Maximum Pressure Drop, Per Vessel | Chlorine Tolerance | Feedwater NTU | Feedwater SDI |
200 psig (1396.8 kPa) | 10-20 GFD (15-35 L.H-1.M-2) | 600 psig (4190 kPa) | 122°F (50°C) | 7.0 -7.5 | 4.0 - 11.0 | 2.0 - 11.5 | 10 psig (69 kPa) | 50 psig (345 kPa) | 1,000 ppm-hrs, Dechlorination recommended | NTU < 1 | SDI < 3 |
• The Langelier Saturation Index (LSI) of the concentrate must be negative to minimize the posibility of calcium scale formation on the membrane surface. At start-up the first two hours of permeate should be discarded because of element preservative. Storage conditions should be less than: <100F, dry, in original carton and not in direct sunlight.